Options
Dr. Oyarzo-Vera, Claudio
Research Outputs
Damage assessment of squat, thin and lightly-reinforced concrete walls by the Park & Ang damage index
2019, Carrillo, Julian, Oyarzo-Vera, Claudio, BlandĂ³n, Carlos
Damage progression indexes are widely used to evaluate the performance of structural elements in buildings and bridges subjected to seismic actions. Although the Park & Ang damage index is currently implemented in several computational tools, the index has not been calibrated for squat and thin reinforced concrete (RC) elements controlled by shear deformations. It has been observed that the equations originally proposed for the Park & Ang damage index are unsuited for these types of structural elements, which are characterized by a failure mode dominated by shear instead of flexural deformations. The index was evaluated in this study for squat, thin and lightly-reinforced concrete walls using experimental data from a program comprising monotonic and reversedcyclic load testing of 25 RC squat cantilever walls. The experimental program included walls, with and without openings, having height-to-length ratios equal to 0.5, 1.0 and 2.0. Full-scale wall thickness and clear height were 100 mm and 2.4 m, respectively. The specimens were built using three different types of concrete (normal-weight, light-weight and self-consolidating) with nominal compressive strength of 15 MPa. A novel formulation for the parameter β included in the Park & Ang damage index was proposed in this study using key variables of the wall specimens such as web reinforcement ratio and cumulative ductility. Comparison between the computed damage index and crack pattern evolution observed in wall specimens at different damage states demonstrated the ability of the model to numerically assess the damage of the wall specimens. Hence, this new formulation proposed for parameter β leads to a better estimation of damage for this particular type of elements when applying the broadly used Park & Ang damage index.