Options
Dr. Nuñez-Castellanos, Eduardo
Nombre de publicación
Dr. Nuñez-Castellanos, Eduardo
Nombre completo
Nuñez Castellanos, Eduardo
Facultad
Email
enunez@ucsc.cl
ORCID
2 results
Research Outputs
Now showing 1 - 2 of 2
- PublicationCyclic behavior of concrete-filled tube columns with bidirectional moment connections considering the local slenderness effectIn this research, the cyclic behavior of concrete-filled thin tube (CFTT) columns with bidirectional moment connections was numerically studied within the context of thin-walled structures. Novel considerations in the design of CFTT columns with slenderness sections are proposed through a parametric study. A total of 70 high-fidelity finite element (FE) models are developed using ANSYS software v2022 calibrated from experimental research using similar 3D joint configurations. Furthermore, a comparison of different width-to-thickness ratios in columns was considered. The results showed that the models with a high slenderness ratio reached a stable cyclic behavior until 0.03 rad of drift, and a flexural strength of 0.8 Mp was reached for 4% of the drift ratio according to the Seismic Provisions. However, this effect slightly decreased the strength and the dissipated energy of the moment connection in comparison to columns with a high ductility ratio. Moreover, an evaluation of concrete damages shows concrete cracked for cyclic loads higher than 3% of drift. Finally, the joint configurations studied can achieve a good performance, avoiding brittle failure mechanisms and ensuring the plastic hinges in the beams.
- PublicationCyclic behavior of the column-tree moment connection with weakened plates: A numerical approachThe use of column-tree connections is common in controlled shop environments due to their cost-effectiveness in achieving ductile welds. Field bolts are also easy to install and inspect. However, there is currently no prequalification available for these connections, their performance is not fully understood, and the cost of aftermath repairs is still a major concern for owners. In this research, analytical and numerical studies were performed to assess the cyclic behavior considering the effects of the bolted splice location, bolt slippage, and splice plate thickness. Fourteen numerical models using the finite element method in ANSYS software were analyzed to evaluate the nonlinear behavior of moment connection configurations in terms of the strength, stiffness, ductility, energy dissipation, and overall cyclic response. The results showed that appropriately proportioned bolted splice connections can meet the requirements for prequalified moment connections. The models complied with the criteria established in AISC 358 and achieved flexural resistance that was higher than 80% of the beam plastic moment at 4% of the interstory drift ratio. The weakened plates concentrated the inelastic action, which allowed us to prevent the brittle behavior and damage to the column, welding, and other components of the moment connection. Complex geometries or specially fabricated parts were not required, providing a cost-effective way to control seismic-related damage. Also, required repairs are based on the replacement of standard parts, reducing operational detentions in facilities. Finally, the moment connection studied is classified as partially restrained (PR) according to the requirements established in AISC 360.