Monotonic response of exposed base plates of columns: Numerical study and a new design method
2020, Díaz, Héctor, Nuñez-Castellanos, Eduardo, Oyarzo-Vera, Claudio
This paper describes a numerical study of the behavior of exposed base plates of columns under the action of axial and bending loads. The aim of this research is to evaluate numerically the failure mechanisms on stiffened and non-stiffened base plates and propose a new design method. The effects of base plate thickness, location of anchor rods, location of stiffeners and tensile strength of anchor rods were considered in the analysis. Sixteen finite elements simulations were performed considering different combinations of the above mentioned parameters. The results show a fragile response in the base plates when high resistance anchor rods are used. The anchor rods worked as fuse elements in base plates with a large thickness or many stiffeners. Additionally, the models with anchor bars located outside of the column flanges showed lower flexural strength and rotational stiffness compared to the models with anchor rods located between column flanges. The simulations showed that the base plate strength was determined by the simultaneous failure mechanisms of two or more components, different to what is stated in current design guides. Finally, the new method is suitable to design base plates with stiffened and not stiffened configurations, which unlike traditional design methods, show a good adjustment with numerical models.
Cyclic behavior of concrete-filled tube columns with bidirectional moment connections considering the local slenderness effect
2024, Dr. Nuñez-Castellanos, Eduardo, Mata-Lemus, Ramón
In this research, the cyclic behavior of concrete-filled thin tube (CFTT) columns with bidirectional moment connections was numerically studied within the context of thin-walled structures. Novel considerations in the design of CFTT columns with slenderness sections are proposed through a parametric study. A total of 70 high-fidelity finite element (FE) models are developed using ANSYS software v2022 calibrated from experimental research using similar 3D joint configurations. Furthermore, a comparison of different width-to-thickness ratios in columns was considered. The results showed that the models with a high slenderness ratio reached a stable cyclic behavior until 0.03 rad of drift, and a flexural strength of 0.8 Mp was reached for 4% of the drift ratio according to the Seismic Provisions. However, this effect slightly decreased the strength and the dissipated energy of the moment connection in comparison to columns with a high ductility ratio. Moreover, an evaluation of concrete damages shows concrete cracked for cyclic loads higher than 3% of drift. Finally, the joint configurations studied can achieve a good performance, avoiding brittle failure mechanisms and ensuring the plastic hinges in the beams.
Cyclic performance of end-plate biaxial moment connection with HSS columns
2020, Dr. Nuñez-Castellanos, Eduardo, Lichtemberg, Roberto, Herrera, Ricardo
This paper presents a numerical study on the seismic performance of end-plate moment connection between I-beam to HSS (hollow structural section) column stiffened by outer diaphragms (EP-HSS). In previous experimental research, this moment connection showed a satisfactory performance according to requirements established in Seismic provisions. However, one type of joint was studied and bidirectional and axial loads were not considered. In this since, several configurations representative of 2D interior joints and 3D interior and exterior joints in a steel building were modeled and subjected to unidirectional or bidirectional cyclic displacements according to protocol in seismic provisions. Firstly, a similar joint configuration was calibrated from experimental data, obtaining an acceptable adjustment. The assessment of seismic performance was based on hysteretic curves, failure mechanisms, stiffness, dissipated energy, and equivalent damping. The results obtained showed a ductile failure modes for 2D and 3D joint configurations with EP-HSS moment connection. The axial load has no significant effect on the moment connection. However, it affects the column strength due to the increase of the stresses in the column wall. Compared with 2D joints, 3D joints reached higher deformations even when a similar number of beams is used. The external diaphragms to the column panel zone provided rigidity in the joints and no degradation of slope for each loop in load/reload segment for elastic loop; therefore, curves without pinching were observed. All inelastic deformation is concentrated mainly in the beams. A moment resistance above 80% of the capacity of the beam at a drift of 4% is achieved in all joints. From the results reached, the use of EP-HSS moment connection with hollow structural section columns is a reliable alternative in seismic zones when steel moment frames are employed.
Assessment of strength reduction factor on concrete moment frames according to the new Venezuelan seismic code
2022, Mata Lemus, Ramón, Idrees Rustom, Ahmad, Sánchez Rodríguez, Javier, Torres Moreno, Ronald, Nuñez-Castellanos, Eduardo, Bustamante-Laissle, Guillermo
Nonlinear static analysis is a validated tool for the seismic evaluation of existing and new structures, specifically for reinforced concrete buildings. In order to assess the performance of reinforced concrete frames designed according to the new Venezuelan seismic code, configurations of low-, medium-, and high-rise concrete buildings are subjected to 20 different load patterns considering the nonlinear behavior according to FEMA P695. A total of 140 concrete frame models were analyzed using modal response spectrum analysis and nonlinear static pushover analysis. The parameters considered for analyzing the models were the response reduction factor (R), the overstrength factor (RΩ), and the ductility factor (Rµ). The results showed a performance controlled by ductile failure mechanisms in low-rise models unlike combined failure mechanisms with columns with plastic hinge in high-rise models. Reduction factor values between 4 and 14 were obtained. In addition, the pushover curves were affected by the load patterns; therefore, it was necessary to identify the representative patterns, refusing the rest of the patterns. A statistical adjustment was performed using a log-normal distribution. The strength reduction factor specified in the new Venezuelan code was higher than the values obtained for the 95% confidence levels according to the distribution assumed in the reinforced concrete frames models. Finally, the strength reduction factor more representative is R = 4.
Numerical study on cyclic response of end-plate biaxial moment connection in box columns
2020, Gallegos, Marco, Nuñez-Castellanos, Eduardo, Herrera, Ricardo
The 2008 Wenchuan-China earthquake showed the importance of considering the bidirectional seismic action as a cause of failure in column hinge mechanisms. Subsequently, the large 2011 Tohoku-Japan earthquake revealed that Special Moment Frames buildings, made of tubular columns (Hollow Structural Section or Built-up Box Section) and rigid connections with I-beams, did not suffer serious damage. However, only the ConXtech® ConXL™ moment connection has been prequalified according to the (American Institute of Construction) AISC Seismic Provisions for use with tubular columns and the rest of connections do not consider biaxial resistance. The research reported herein investigated the cyclic response of box-columns joints, connected to I beams using the four-bolt extended endplate connection, subjected to bidirectional bending and axial load on the column. To conduct the study, complex nonlinear finite element models (FEMs) of several I beam to box column joint configurations were constructed and analyzed under cyclic loading using the ANSYS software. The results reveal that the failure is concentrated in the beams of all joint configurations except for the columns with axial load equal to 75% of the column capacity, where a combined failure mechanism is achieved. The energy dissipation capacity of joints with a greater number of beams is lower than joints with fewer beams. The bidirectional effect of the seismic action and the level of axial load must be considered to avoid the formation of a column-hinge fragile failure mechanism also the behavior exhibited by 3D joints is more realistic than 2D joints according to real structures.
Cyclic behavior of the column-tree moment connection with weakened plates: A numerical approach
2023, Dr. Nuñez-Castellanos, Eduardo, Matthews, Pablo
The use of column-tree connections is common in controlled shop environments due to their cost-effectiveness in achieving ductile welds. Field bolts are also easy to install and inspect. However, there is currently no prequalification available for these connections, their performance is not fully understood, and the cost of aftermath repairs is still a major concern for owners. In this research, analytical and numerical studies were performed to assess the cyclic behavior considering the effects of the bolted splice location, bolt slippage, and splice plate thickness. Fourteen numerical models using the finite element method in ANSYS software were analyzed to evaluate the nonlinear behavior of moment connection configurations in terms of the strength, stiffness, ductility, energy dissipation, and overall cyclic response. The results showed that appropriately proportioned bolted splice connections can meet the requirements for prequalified moment connections. The models complied with the criteria established in AISC 358 and achieved flexural resistance that was higher than 80% of the beam plastic moment at 4% of the interstory drift ratio. The weakened plates concentrated the inelastic action, which allowed us to prevent the brittle behavior and damage to the column, welding, and other components of the moment connection. Complex geometries or specially fabricated parts were not required, providing a cost-effective way to control seismic-related damage. Also, required repairs are based on the replacement of standard parts, reducing operational detentions in facilities. Finally, the moment connection studied is classified as partially restrained (PR) according to the requirements established in AISC 360.
Bidirectional response of weak-axis end-plate moment connections: Numerical approach
2020, Dr. Nuñez-Castellanos, Eduardo, Parraguez, Guillermo, Herrera, Ricardo
Brittle failure mechanisms can affect the seismic performance of structures composed of intersecting moment resisting frames, if the biaxial effects are not considered. In this research, the bidirectional cyclic response of H-columns with weak-axis moment connections was studied using numerical models. Several configurations of joints with bidirectional effects and variable axial loads were studied using the finite element method (FEM) in ANSYS v17.2 software. The results obtained showed a ductile behavior when cyclic loads are applied. No evidence of brittle failure mechanisms in the studied joint configurations was observed, in line with the design philosophy established in current seismic provisions. However, beams connected to the column minor axis reached a partially restrained behavior. Joints with four beams connected to the column exhibited a partially restrained behavior for all axial load levels. An equivalent force displacement method was used to compare the hysteretic response of 2D and 3D joints, obtaining higher deformations in 3D joints with respect to 2D joints with a similar number of connected beams. Consequently, design procedures are not capable of capturing the 3D deformation phenomenon.
Cyclic behavior of hollow section beam–column moment connection: Experimental and numerical study
2020, Dr. Nuñez-Castellanos, Eduardo, Boainy, Nwar, González, Freddy, Torres, Ronald, Picón, Ricardo, Guerrero, Néstor
Steel buildings with tubular columns showed a satisfactory performance during the Honshu (2011) earthquake, unlike steel buildings in the 1994 Northridge and 1995 Kobe earthquakes, where welded moment connections showed damage in their joints. In this research, a lateral joint using a hollow structural section (HSS)-beam and HSS-column subjected to cyclic displacement was performed. Three large-scale specimens were tested and a numerical model was calibrated, reaching a good adjustment. Later, several configurations of beams and columns were evaluated using finite element (FE) models from the numerical model previously calibrated. A flexural resistance higher 0.80 Mp at 0.04 [rad] was obtained for all cases studied. The ductility factor in the 3 specimens was lower than 2.5, therefore a non-ductile behavior was controlled in the connection. This aspect is very important although a 0.8 Mp at 0.04 [rad] was achieved. Finally, the typical welded moment connection can be improved using the bolted moment connection, which allows the concentration of inelastic incursion in the beam compared with the welded solution. However, a non-ductile behavior derived from local buckling in flanges of a tubular beam can affect the seismic performance.
A Simplified Framework to Integrate Databases with Building Information Modeling for Building Energy Assessment in Multi-Climate Zones
2024, Lobos Calquín, Danny, Mata, Ramón, Vielma, Juan Carlos, Beaumont-Sepulveda, Juan Carlos, Mg. Correa-Rogel, Claudio, Dr. Nuñez-Castellanos, Eduardo, Forcael, Eric, Blanco, David, Pulgar, Pablo
BIM models are seldom used for the energy certification of buildings. This paper discusses the advantages of linking two important fields: building information modeling (BIM) and building environmental assessment methods (BEAM), presented as a rating system and a proposal for the Chilean context. The state of the art in both fields around the world is discussed, with an in-depth examination of current BIM software and related applications, followed by a discussion about previous research on integrating them. A lack of interoperability and data losses between BIM and BEM were found. A new tool is presented that addresses these challenges to ensure accurate rating system data, and this new framework is based on database exchange and takes crucial information from BIM to BEAM platforms. The development of the method includes BIM programming (API), database links, and spreadsheets for a Chilean building energy certification through a new tool, also applicable to multiclimactic zones. This new semi-automatic tool allows architects to model their design in a BIM platform and use this information as input for the energy certification process. The potential and risks of this method are discussed. Several improvements and enhancements of the energy certification process were found when incorporating this new framework in comparison to current methodologies.
Damage assessment of the May 31st, 2019, Talcahuano tornado, Chile
2020, Dr. Aranguiz-Muñoz, Rafael, Dr. Oyarzo-Vera, Claudio, Dr. Nuñez-Castellanos, Eduardo, Dra. Bull-Torres, Maria, Saez, Boris, Gutierrez, Gladys, Quinones, Catalina, Bobadilla, Romina
On May 31st, 2019, a tornado hit the city of Talcahuano, Chile, generating significant damage to structures and leaving one person dead. The objective of the present paper is to report on damage to structures in Talcahuano. A preliminary survey was performed by the Municipality of Talcahuano and covered the entire affected area with a cellphone web application used to report the severity and distribution of damage. A more comprehensive damage survey was conducted in the Brisa del Sol neighborhood in the Medio Camino area by the UCSC team to assess the damage distribution within an area with well-defined and homogeneous building typologies. The results of the field surveys showed that the tornado behaved as a skipping tornado and that most damage to houses consisted of wall opening damage, roof sheathing failure, and wall cover removal (EF0), followed by partial roof removal(EF1). It was noticeable that self-built systems (house additions) were more damaged than original houses, which may be explained by the fact that such structures do not always meet minimum building standards. It is recommended that field surveys conducted by municipalities and the Ministry of Social Development considertypical damage types rather than just categories such as minor, moderate, or major. Finally, it is recommendedthat the feasibility of implementing mitigation measures such as stricter wind load provisions and dual-objective tornado design philosophy in the Concepci´on-Talcahuano area be analyzed.