Research Outputs

Now showing 1 - 3 of 3
No Thumbnail Available
Publication

Strong column-weak beam relationship of 3D steel joints with tubular columns: Assessment, validation and design proposal

2024, Dr. Nuñez-Castellanos, Eduardo, Mata-Lemus, Ramón

The study of moment connections in steel structures subjected to cyclic loads has been extensively studied, providing a great number of requirements, including the strong column-weak beam relationship, to guarantee a satisfactory cyclic performance. However, investigations on the cyclic performance of moment connections considering the bidirectional and axial load effects simultaneously with tubular columns are limited. This study aims to assess and validate the strong column-weak beam relationship of 3D steel moment connections using reduced order models. The simplified model (reduced order model) approach was employed to extend the range of beam and column elements sizes and reduce the experimental and computational costs. These models were calibrated from full-scale experimental studies. A great number of configurations with different beam and column sizes without loss of reliability and structural representativeness of the studied phenomenon were studied. A total of 13640 simplified models were developed. Results show a cyclic behavior controlled by the strong column-weak beam relationship to modify the joint’s failure mechanism. The increasing of strong column-weak beam relationship and the biaxial effect caused degradation of the strength and stiffness as well as in dissipated energy. An optimal strong column-weak beam relationship was obtained for all joint configurations analyzed. Finally, a robust design procedure is proposed, ensuring the cyclic behavior of end-plate moment connection with built-up box column including biaxial effect and axial load. Therefore, the use of this type of moment connection can be used in special and intermediate moment frames designed according to Seismic provisions.

No Thumbnail Available
Publication

Parametric study of 3D steel moment connections with built-up box column subjected to biaxial cyclic loads

2022, Dr. Nuñez-Castellanos, Eduardo, Mata-Lemus, Ramón

In this numerical research, the variation of cyclic behavior of beam-to-box column connection was studied. Dimensional and load conditions were parametrically evaluated with the goal of assessing the applicability and use of this biaxial moment connection according to the Seismic Provisions, such as bending strength and rotation capacity, secant and tangent stiffness, dissipated energy and strong column-weak beam relationship. A total of 83 different models of 3D connections were developed using in ANSYS software with the load at the top of the column. Results show a cyclic behavior not controlled by axial load. However, the variations of clear span to depth beam ratio caused degradation of the strength, secant and tangent stiffness as well as in dissipated energy. The 80% of plastic moment of beam and rotation at 4% interstory drift were reached for all models analyzed according to criteria established in AISC 341. Finally, the configurations designed with low levels of axial load are controlled by the design of the web panel zone shear, while configurations designed for high levels of axial load are controlled by the strong column-weak beam criterion.

Thumbnail Image
Publication

Assessment of web panel zone in built-up box columns subjected to bidirectional cyclic loads

2023, Mata, Ramón, Maureira-Carsalade, Nelson, Nuñez-Castellanos, Eduardo, Sanhueza-Espinoza, Frank, Roco, Ángel

The behavior of the web panel zone has a direct effect on the cyclic performance of steel moment connections. While the mechanisms of web panel zone failure are known under cyclic load, little is known about the behavior of the web panel zone under bidirectional loads in bolted connections. Using experimental tests and calibrated numerical models, this research evaluated the web panel zone behavior under unidirectional and bidirectional cyclic loads. The results showed that bidirectional load can modify the stress and strain distribution in the web panel zone. Moreover, the increasing of the width-to-thickness ratio of the column influences the failure mechanism of the joint configuration and increases the plastic incursion in the column. These data demonstrate that bidirectional effects improve the web panel zone performance under cyclic loads.