Options
Dr. Sanhueza-Espinoza, Frank
Nombre de publicación
Dr. Sanhueza-Espinoza, Frank
Nombre completo
Sanhueza Espinoza, Frank Emilio
Facultad
Email
franksanhueza@ucsc.cl
ORCID
3 results
Research Outputs
Now showing 1 - 3 of 3
- PublicationNumerical study on seismic response of steel storage racks with roller type Isolator(MDPI, 2021)
; ; ; ;Álvarez-Figueroa, OscarRoco-Videla, ÁngelThis research evaluates the effectiveness of using a roller-type base isolation device with tensile strength in reducing the dynamic response of industrial steel storage racks. These were subjected to a seismic input acting separately in both directions of the structure. The seismic record obtained from the earthquake that occurred in Llolleo, Chile, on 3 March 1985, was used as input. This earthquake was scaled in the frequency domain, adjusting its response spectrum to coincide with the design spectrum required by NCh2745. In the calculations of this spectrum, the most hazardous seismic zone (zone 3) and soft soil (soil III) that amplifies the effect of the low frequencies of the earthquake were considered. These frequencies are the ones that have the most affect on flexible structures such as high racks and systems with base isolation. Numerical time-history analyses were performed in fixed base racks and base isolation racks. In both cases, the models include semi-rigid connections with capacity for plastic deformation and energy dissipation. Parametric analyses were carried out considering the most relevant variables, using an algorithm programmed in MATLAB software. The maximum relative displacement, maximum basal shear load, and maximum absolute floor acceleration were considered as responses of interest. The results showed the effectiveness of using the base isolation device by reducing the absolute accelerations between approximately 75% and 90%, compared to the same fixed rack at its base. This makes it possible to reduce the vulnerability of the stored load to overturn under the action of a severe earthquake. - PublicationCyclic behavior of 3D moment connections subjected to bidirectional load: Experimental approach(Engineering Structures, 2023)
; ;Bustos-Figueroa, Juan ;Mata-Lemus, Ramón; Lapeña-Mañero, PabloThis paper presents an experimental research to assess the cyclic behavior of a bolted moment connection with the use of optimized end-plate connected to built-up box column subassemblies subjected to bidirectional and unidirectional loading. Seven real scale specimens were tested: three specimens with four beams connected to column as interior joint, two specimens with two beams connected as corner joint configuration and two specimens with two beams connected to column as interior joint, according the protocol established in AISC Seismic provisions. The seismic performance was evaluated in terms of hysteretic behavior, failure mechanism, stiffness and dissipated energy. The joints studied were manufactured from of hot-rolled I-beams and square built-up box columns. The elements of connection such as bolts, welding, outer stiffeners and end-plates were designed to remain in elastic range from the flexural expected capacity of beams. The results showed that the required minimum moment of 0.8Mp at 0.04 rad of drift angle was achieved for all specimens tested. However, a higher stiffness and resistance was reached in configuration with unidirectional load (interior joint) in comparison to joint subjected to bidirectional load (corner joint). The damage was concentrated uniquely in beams, while an elastic behavior in columns and connection components was reached for 0.04 rad of drift angle. Finally, this moment connection configuration can be used as an alternative to design buildings with special moment frames under bidirectional loading considering the cyclic behavior of joints evaluated. - PublicationAssessment of web panel zone in built-up box columns subjected to bidirectional cyclic loads(Buildings, 2023)
;Mata, Ramón; ; ; Roco, ÁngelThe behavior of the web panel zone has a direct effect on the cyclic performance of steel moment connections. While the mechanisms of web panel zone failure are known under cyclic load, little is known about the behavior of the web panel zone under bidirectional loads in bolted connections. Using experimental tests and calibrated numerical models, this research evaluated the web panel zone behavior under unidirectional and bidirectional cyclic loads. The results showed that bidirectional load can modify the stress and strain distribution in the web panel zone. Moreover, the increasing of the width-to-thickness ratio of the column influences the failure mechanism of the joint configuration and increases the plastic incursion in the column. These data demonstrate that bidirectional effects improve the web panel zone performance under cyclic loads.