Publication:
FCS-MPC without steady-state error applied to a grid-connected cascaded H-Bridge multilevel inverter

cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid801af79d-9d43-4581-b6d6-7e0239ba984c
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department801af79d-9d43-4581-b6d6-7e0239ba984c
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
dc.contributor.authorDr. Espinosa-Neira, Eduardo
dc.contributor.authorBaier, Carlos
dc.contributor.authorRamirez, Roberto
dc.contributor.authorMarciel, Esteban
dc.contributor.authorHernandez, Jesus
dc.contributor.authorMelin, Pedro
dc.date.accessioned2024-10-03T18:12:41Z
dc.date.available2024-10-03T18:12:41Z
dc.date.issued2021
dc.description.abstractCascaded H-bridge multilevel (CHB-ML) inverters are an attractive alternative for supplying power to ac grids as they have high reliability and offer an acceptable quality of voltage at their output terminals. In order to achieve efficient operation in these CHB-ML inverters, they must work at low switching frequencies. The finite-control set model predictive control (FCS-MPC) scheme is a very intuitive strategy for controlling this type of converter, but traditional FCS-MPC algorithms generally have a steady-state error when operating at low sampling frequencies and/or if there are parameters mismatch in the prediction model, regarding those of the real system. In this article, a grid-connected CHB-ML inverter that uses an improved FCS-MPC scheme is proposed. The proposed strategy eliminates the steady-state error in an MPC operating at low sampling frequencies and maintains correct operation when a change in the control reference occurs. Experimental results from a grid-connected CHB-ML inverter with three units (seven levels) demonstrate the feasibility of the proposal.
dc.identifier.doi10.1109/TPEL.2021.3065003
dc.identifier.urihttps://repositorio.ucsc.cl/handle/25022009/11330
dc.languageeng
dc.publisherIEEE
dc.subjectCascade H-bridge (CHB) inverters
dc.subjectFinite-control set model predictive control (FCS-MPC)
dc.subjectMultilevel inverters
dc.subjectPredictive control
dc.subjectZero steady-state error
dc.titleFCS-MPC without steady-state error applied to a grid-connected cascaded H-Bridge multilevel inverter
dc.typeartículo
dspace.entity.typePublication
oairecerif.author.affiliationFacultad de Ingeniería
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
Files