Publication:
Generalized Correlations for the Estimation of Condensate Power in Flooded Cylinders

cris.virtual.author-orcid0000-0002-3947-1710
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.departmentFacultad de Ingeniería
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid9520fb57-f049-4e07-a960-4ef2689cd3bb
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department9520fb57-f049-4e07-a960-4ef2689cd3bb
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
dc.contributor.authorDr. Ramírez-Arias, Guillermo
dc.contributor.authorValenzuela, M. Anibal
dc.contributor.authorLorenz, Robert D
dc.date.accessioned2025-05-12T13:47:53Z
dc.date.available2025-05-12T13:47:53Z
dc.date.issued2014
dc.description.abstractCondensate accumulated inside dryer cylinders will produce an increased power demand and eventually the inability of the dryer drive to accelerate the section. In a previous paper, these authors presented an online estimation algorithm capable of detecting the presence of condensate during a section starting. In this paper, a complete set of tests is run over two experimental cylinders covering up to 40% of cylinder volumes, and the complete set of power curves are reported and analyzed. Specifically, the presence of a combined cascading-rimming region in the medium to high condensate loads is confirmed. This combined mode modifies the pattern followed by the maximum power in the low condensate region. Using these data, high-order and simplified correlations are proposed for the estimation of condensate in flooded dryer cylinders. These new correlations increase the capacity of the online estimation algorithm to give good estimations of the condensate load present inside the dryer cylinders up to 55 mm of rim thickness.
dc.identifier.doi10.1109/TIA.2013.2279907
dc.identifier.issn0093-9994
dc.identifier.issn1939-9367
dc.identifier.urihttps://repositorio.ucsc.cl/handle/25022009/12362
dc.languageeng
dc.publisherIEEE Xplore
dc.relation.ispartofIEEE Transactions on Industry Applications
dc.relation.journalIEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
dc.rightsregistro bibliográfico
dc.subjectCondensate observer
dc.subjectDryer cylinders
dc.subjectPower requirements
dc.subjectPaper machine
dc.titleGeneralized Correlations for the Estimation of Condensate Power in Flooded Cylinders
dc.typeartículo
dspace.entity.typePublication
oaire.citation.issue2
oaire.citation.volume50
oairecerif.author.affiliationFacultad de Ingeniería
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
Files
License bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
license.txt
Size:
276 B
Format:
Item-specific license agreed to upon submission
Description: