Publication:
Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity

cris.sourceIdoai:repositorio.ucsc.cl:25022009/3039
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcidbd352f78-5038-4547-829d-cb89fe589b90
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentbd352f78-5038-4547-829d-cb89fe589b90
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
dc.contributor.authorMartinez Garcia, Dario
dc.contributor.authorRodriguez Perea, Angela
dc.contributor.authorBarboza, Paola
dc.contributor.authorDr. Ulloa-Díaz, David
dc.contributor.authorJerez Mayorga, Daniel
dc.contributor.authorChirosa, Ignacio
dc.contributor.authorChirosa Ríos, Luis Javier
dc.date.accessioned2021-09-02T00:44:57Z
dc.date.accessioned2023-09-11T14:57:43Z
dc.date.available2021-09-02T00:44:57Z
dc.date.created2021-09-02T00:44:57Z
dc.date.issued2020
dc.description.abstractBackground. The evaluation of the force in internal rotation (IR) and external rotation (ER) of the shoulder is commonly used to diagnose possible pathologies or disorders in the glenohumeral joint and to assess patient’s status and progression over time. Currently, there is new technology of multiple joint isokinetic dynamometry that allows to evaluate the strength in the human being. The main purpose of this study was to determine the absolute and relative reliability of concentric and eccentric internal and external shoulder rotators with a functional electromechanical dynamometer (FEMD). Methods. Thirty-two male individuals (21.46 ± 2.1 years) were examined of concentric and eccentric strength of shoulder internal and external rotation with a FEMD at velocities of 0.3 m s−1 and 0.6 m s−1 . Relative reliability was determined by intraclass correlation coefficients (ICC). Absolute reliability was quantified by standard error of measurement (SEM) and coefficient of variation (CV). Systematic differences across velocities testing circumstances, were analyzed with dependent t tests or repeated measures analysis of variance in case of two or more than two conditions, respectively. Results. Reliability was high to excellent for IR and ER on concentric and eccentric strength measurements, regardless of velocity used (ICC: 0.81–0.98, CV: 5.12–8.27% SEM: 4.06–15.04N). Concentric outcomes were more reliable than eccentric due to the possible familiarization of the population with the different stimuli. Conclusion. All procedures examined showed high to excellent reliability for clinical use. However, a velocity of 0.60 m s−1 should be recommended for asymptomatic male patients because it demands less time for evaluation and patients find it more comfortable.
dc.identifier.doi10.7717/peerj.9951
dc.identifier.urihttps://repositorio.ucsc.cl/handle/25022009/8701
dc.languageeng
dc.publisherPEERJ
dc.rightsacceso abierto
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectKinesiology
dc.subjectOrthopedics
dc.subjectIsokinetic
dc.subjectShoulder
dc.subjectStrength
dc.subjectVelocity
dc.subject.ocdeCiencias médica y de la salud::Ciencias de la salud
dc.titleReliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
dc.typeartículo
dspace.entity.typePublication
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliationFacultad de Educación
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
relation.isAuthorOfPublicationbd352f78-5038-4547-829d-cb89fe589b90
Files