Publication: A new reliable device to assess trunk extensors strength
cris.virtual.author-orcid | 0000-0001-7677-0763 | |
cris.virtual.author-orcid | 0000-0003-1288-1397 | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | Facultad de Educación | |
cris.virtual.department | Facultad de Educación | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | 814cf028-a901-4e1d-a157-cb3f0a804f14 | |
cris.virtualsource.author-orcid | bd352f78-5038-4547-829d-cb89fe589b90 | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.author-orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | 814cf028-a901-4e1d-a157-cb3f0a804f14 | |
cris.virtualsource.department | bd352f78-5038-4547-829d-cb89fe589b90 | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
dc.contributor.author | Barboza-González, Paola | |
dc.contributor.author | Dr. Ulloa-Díaz, David | |
dc.contributor.author | Reyes-Ferrada, Waleska | |
dc.contributor.author | Chirosa-Ríos, Luis | |
dc.contributor.author | Chirosa-Ríos, Ignacio | |
dc.contributor.author | Martínez-García, Darío | |
dc.contributor.author | Jerez-Mayorga, Daniel | |
dc.contributor.author | Rodríguez-Perea, Ángela | |
dc.date.accessioned | 2024-06-07T15:41:06Z | |
dc.date.available | 2024-06-07T15:41:06Z | |
dc.date.issued | 2021 | |
dc.description.abstract | Purpose: This study aimed to examine the reliability of trunk extensor strength assessment with a functional electromechanical dynamometer (FEMD). Methods: Thirty-one men performed strength assessment at different velocities (V) (V1 = 0.15 m·s−1, V2 = 0.30 m·s−1, V3 = 0.45 m·s−1) and range of movement (R) (R1 = 25% cm; R2 = 50% cm), and isometric contraction at 90º. Reliability was obtained through the intraclass correlation coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results: The absolute reliability provided stable repeatability of the average eccentric strength in the V1R1 condition (CV = 9.52%) and the maximum eccentric strength in V1R1 (CV = 9.63%) and V2R2 (CV = 9.66%). The relative reliability of the trunk extensor’s average strength was good (ICC = 0.77–0.83) for concentric and good (ICC = 0.78–0.85) and moderate (ICC = 0.67–0.74) for eccentric contraction. Also, good (ICC = 0.77–0.81) and moderate (ICC = 0.55–0.74) reliability of the maximum strength were obtained for concentric and eccentric contraction. The most reliable manifestation to evaluate the concentric (CV = 11.33%) and eccentric (CV = 9.52%) strength was the average strength in the V1R1 condition and the maximum strength (CV = 10.29%) to isometric assessment. The average concentric strength in the V2R2 condition (r = 0.69) and the maximum eccentric strength in the V1R1 condition (r = 0.65) were the best related to the maximum isometric strength. Conclusions: FEMD is a highly reliable device to evaluate trunk extensors strength. | |
dc.identifier.doi | 10.37190/ABB-01965-2021-05 | |
dc.identifier.uri | https://repositorio.ucsc.cl/handle/25022009/10513 | |
dc.language | eng | |
dc.publisher | Acta of Bioengineering and Biomechanics | |
dc.relation.uri | doi.org/10.37190/ABB-01965-2021-05 | |
dc.subject | Isokinetic | |
dc.subject | Core | |
dc.subject | Strength | |
dc.subject | Reproducibility | |
dc.subject | Dynamometer | |
dc.title | A new reliable device to assess trunk extensors strength | |
dc.type | artículo | |
dspace.entity.type | Publication | |
oairecerif.author.affiliation | Facultad de Educación | |
oairecerif.author.affiliation | Facultad de Educación | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
oairecerif.author.affiliation | #PLACEHOLDER_PARENT_METADATA_VALUE# |