Publication:
A new reliable device to assess trunk extensors strength

cris.virtual.author-orcid0000-0001-7677-0763
cris.virtual.author-orcid0000-0003-1288-1397
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.departmentFacultad de Educación
cris.virtual.departmentFacultad de Educación
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid814cf028-a901-4e1d-a157-cb3f0a804f14
cris.virtualsource.author-orcidbd352f78-5038-4547-829d-cb89fe589b90
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department814cf028-a901-4e1d-a157-cb3f0a804f14
cris.virtualsource.departmentbd352f78-5038-4547-829d-cb89fe589b90
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
dc.contributor.authorBarboza-González, Paola
dc.contributor.authorDr. Ulloa-Díaz, David
dc.contributor.authorReyes-Ferrada, Waleska
dc.contributor.authorChirosa-Ríos, Luis
dc.contributor.authorChirosa-Ríos, Ignacio
dc.contributor.authorMartínez-García, Darío
dc.contributor.authorJerez-Mayorga, Daniel
dc.contributor.authorRodríguez-Perea, Ángela
dc.date.accessioned2024-06-07T15:41:06Z
dc.date.available2024-06-07T15:41:06Z
dc.date.issued2021
dc.description.abstractPurpose: This study aimed to examine the reliability of trunk extensor strength assessment with a functional electromechanical dynamometer (FEMD). Methods: Thirty-one men performed strength assessment at different velocities (V) (V1 = 0.15 m·s−1, V2 = 0.30 m·s−1, V3 = 0.45 m·s−1) and range of movement (R) (R1 = 25% cm; R2 = 50% cm), and isometric contraction at 90º. Reliability was obtained through the intraclass correlation coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results: The absolute reliability provided stable repeatability of the average eccentric strength in the V1R1 condition (CV = 9.52%) and the maximum eccentric strength in V1R1 (CV = 9.63%) and V2R2 (CV = 9.66%). The relative reliability of the trunk extensor’s average strength was good (ICC = 0.77–0.83) for concentric and good (ICC = 0.78–0.85) and moderate (ICC = 0.67–0.74) for eccentric contraction. Also, good (ICC = 0.77–0.81) and moderate (ICC = 0.55–0.74) reliability of the maximum strength were obtained for concentric and eccentric contraction. The most reliable manifestation to evaluate the concentric (CV = 11.33%) and eccentric (CV = 9.52%) strength was the average strength in the V1R1 condition and the maximum strength (CV = 10.29%) to isometric assessment. The average concentric strength in the V2R2 condition (r = 0.69) and the maximum eccentric strength in the V1R1 condition (r = 0.65) were the best related to the maximum isometric strength. Conclusions: FEMD is a highly reliable device to evaluate trunk extensors strength.
dc.identifier.doi10.37190/ABB-01965-2021-05
dc.identifier.urihttps://repositorio.ucsc.cl/handle/25022009/10513
dc.languageeng
dc.publisherActa of Bioengineering and Biomechanics
dc.relation.uridoi.org/10.37190/ABB-01965-2021-05
dc.subjectIsokinetic
dc.subjectCore
dc.subjectStrength
dc.subjectReproducibility
dc.subjectDynamometer
dc.titleA new reliable device to assess trunk extensors strength
dc.typeartículo
dspace.entity.typePublication
oairecerif.author.affiliationFacultad de Educación
oairecerif.author.affiliationFacultad de Educación
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
Files