Options
Dr. Oyarzo-Vera, Claudio
Nombre de publicaciĂ³n
Dr. Oyarzo-Vera, Claudio
Nombre completo
Oyarzo Vera, Claudio Andres
Facultad
Email
coyarzov@ucsc.cl
ORCID
7 results
Research Outputs
Now showing 1 - 7 of 7
- PublicationMonotonic response of exposed base plates of columns: Numerical study and a new design methodThis paper describes a numerical study of the behavior of exposed base plates of columns under the action of axial and bending loads. The aim of this research is to evaluate numerically the failure mechanisms on stiffened and non-stiffened base plates and propose a new design method. The effects of base plate thickness, location of anchor rods, location of stiffeners and tensile strength of anchor rods were considered in the analysis. Sixteen finite elements simulations were performed considering different combinations of the above mentioned parameters. The results show a fragile response in the base plates when high resistance anchor rods are used. The anchor rods worked as fuse elements in base plates with a large thickness or many stiffeners. Additionally, the models with anchor bars located outside of the column flanges showed lower flexural strength and rotational stiffness compared to the models with anchor rods located between column flanges. The simulations showed that the base plate strength was determined by the simultaneous failure mechanisms of two or more components, different to what is stated in current design guides. Finally, the new method is suitable to design base plates with stiffened and not stiffened configurations, which unlike traditional design methods, show a good adjustment with numerical models.
- PublicationNon-Destructive assessment of the elastic properties of Low-Grade CLT panels(Forests, 2021)
; ; ;Opazo-Vega, Alexander ;Benedetti, FrancoNuñez-Decap, MarioThe use of cross-laminated timber panels (CLT) made of low-grade structural timber has steadily increased in developing countries. These panels usually present several natural defects, which can cause a high local variation of their orthotropic elastic properties, generating future structural serviceability problems. Our work aims to estimate the local variability of the elastic properties in low-grade CLT panels by combining nondestructive transverse vibration testing, numerical simulations, and regional sensitivity analysis (RSA). Four three-layer Radiata pine CLT panels were subjected to transverse vibration tests with supports at four points. Besides, a series of numerical simulations of the panels, considering the local variability of the elastic properties of the panels in eight zones, were carried out using the finite element method. Then, RSA analysis was performed to study in which ranges of values the panels’ elastic properties generated lower differences between the measured versus simulated dynamic properties. Finally, a structural quality control indicator was proposed for the CLT panels based on keeping low the probability that the elastic properties in the central zones do not exceed minimum acceptable values. The results obtained suggest that the proposed methodology is suitable for segregating CLT panels with high concentrations of defects such as pith presence. - PublicationSeismic and coastal vulnerability assessment model for buildings in ChileThis article proposes a vulnerability assessment model for evaluating buildings’ expected seismic performance, as well as their vulnerability to tsunamis. The objective of this assessment is to provide appropriate information for decision makers regarding the need of repairs and reinforcement of buildings or other mitigation measures that need to be applied in a territory. A procedure for assessing seismic vulnerability and another methodology for evaluating tsunami vulnerability faced by coastal structures is presented. Finally, a method that integrates both procedures is proposed, providing a combined index of vulnerability. The assessment model was applied to the central area of the city of Talcahuano, Chile, which was affected by the 2010 Maule earthquake and tsunami.
- PublicationVariation in the modal response of retrofitted unreinforced masonry walls at different levels of damageThis article presents the results of an experimental campaign conducted on a set of four unreinforced masonry walls at full scale. The purpose of this study is to assess, using non-destructive methods, the impact of retrofitting and damage on the modal response of masonry wall systems. Each wall underwent a sequence of increasing cyclic displacements applied by an actuator at the upper end of the specimen. Modal tests based on vibrations were performed both before and after rehabilitation, as well as during the sequence of increasing displacements. It was demonstrated that frequencies can identify progressive damage when the maximum crack is about to occur, as well as the effect of wall retrofitting when mass contribution is considerable. However, the modal assurance criterion indicator (MAC) fails to properly identify a trend of decreasing correlations as progressive damage increases; instead, it is sensitive to detecting maximum crack and instability conditions. Furthermore, it was determined that the coordinated modal assurance criterion indicator (COMAC) does not identify the damage distribution as expected. However, the cumulative COMAC provides a useful tool for quick visualization and interpretation of COMAC behavior. Finally, a novel damage indicator was tested, MACVF, which improves the trend and successfully identifies the most damage-sensitive mode, especially when the maximum level of damage is reached, giving MAC values below 80%. In addition, frequency variations ranged from 70% to 110% when TRM and WWM retrofitting techniques were applied.
- PublicationDamage assessment of the May 31st, 2019, Talcahuano tornado, Chile(International journal of disaster risk reduction, 2020)
; ; ; ; ;Saez, Boris ;Gutierrez, Gladys ;Quinones, CatalinaBobadilla, RominaOn May 31st, 2019, a tornado hit the city of Talcahuano, Chile, generating significant damage to structures and leaving one person dead. The objective of the present paper is to report on damage to structures in Talcahuano. A preliminary survey was performed by the Municipality of Talcahuano and covered the entire affected area with a cellphone web application used to report the severity and distribution of damage. A more comprehensive damage survey was conducted in the Brisa del Sol neighborhood in the Medio Camino area by the UCSC team to assess the damage distribution within an area with well-defined and homogeneous building typologies. The results of the field surveys showed that the tornado behaved as a skipping tornado and that most damage to houses consisted of wall opening damage, roof sheathing failure, and wall cover removal (EF0), followed by partial roof removal(EF1). It was noticeable that self-built systems (house additions) were more damaged than original houses, which may be explained by the fact that such structures do not always meet minimum building standards. It is recommended that field surveys conducted by municipalities and the Ministry of Social Development considertypical damage types rather than just categories such as minor, moderate, or major. Finally, it is recommendedthat the feasibility of implementing mitigation measures such as stricter wind load provisions and dual-objective tornado design philosophy in the Concepci´on-Talcahuano area be analyzed. - PublicationDiagnĂ³stico estructural de un edificio de hormigĂ³n armado basado en su perfil bio-sĂsmico y un anĂ¡lisis dinĂ¡mico incrementalEn este estudio se presenta la evaluaciĂ³n global de la salud estructural de un edificio habitacional de 14 pisos de altura, potencialmente vulnerable a sufrir daños significativos debido a terremotos y tsunamis. Este edificio fue construido en el año 2013 y estĂ¡ ubicado en la zona costera de ConcepciĂ³n (Chile), en el Ă¡rea afectada por el terremoto Mw = 8.8 del Maule 2010. La evaluaciĂ³n estructural se realizĂ³ combinando ensayos destructivos (extracciĂ³n y ensayo de testigos) y no-destructivos (esclerĂ³metro). Utilizando la informaciĂ³n obtenida experimentalmente se generĂ³ un modelo numĂ©rico lineal del edificio, el cual fue utilizado para evaluar la salud global del edificio mediante una metodologĂa llamada perfil bio-sĂsmico y un anĂ¡lisis dinĂ¡mico incremental. Los resultados de este estudio demuestran que el edificio presentarĂa un buen desempeño frente a eventos sĂsmicos de gran envergadura,pero serĂa susceptible a presentar daño producto de los desplazamientos que experimentarĂa, ya que estos superan el rango de desplazamiento permitido por las juntas de expansiĂ³n sĂsmica.
- PublicationNon-Destructive assessment of the dynamic elasticity modulus of Eucalyptus nitens timber boardsEucalyptus nitens is a fast-growing wood species with a relevant presence in countries like Australia and Chile. The sustainable construction goals have driven the search of structural applications for Eucalyptus nitens; however, this process has been complicated due to the defects usually presented in these timber boards. This study aims to evaluate the dynamic elasticity modulus(Exd) of Eucalyptus nitens timber boards through non-destructive vibration-based tests. Thirty-six timber boards with different levels of knots and cracks were instrumented and tested in a simply supported condition by measuring longitudinal and transverse vibrations. In the first stage, the Exd was calculated globally through simplified normative formulas. Then, in a second stage, the local variability of the Exd was estimated using operational modal analysis (OMA), finite element numerical simulations (FEM), and regional sensitivity analysis (RSA). The positive correlation found between the global static modulus of elasticity and Exd suggests that non-destructive techniques could be used as a reliable and fast alternative for the assessment of bending stiffness. Finally, the proposed method to estimate the local variability of Exdt based on the combination of OMA, FEM,and RSA techniques was useful to improve the structural selection process of timber boards forlightweight social housing floors.