Options
Dr. Nuñez-Castellanos, Eduardo
Research Outputs
Monotonic response of exposed base plates of columns: Numerical study and a new design method
2020, Díaz, Héctor, Nuñez-Castellanos, Eduardo, Oyarzo-Vera, Claudio
This paper describes a numerical study of the behavior of exposed base plates of columns under the action of axial and bending loads. The aim of this research is to evaluate numerically the failure mechanisms on stiffened and non-stiffened base plates and propose a new design method. The effects of base plate thickness, location of anchor rods, location of stiffeners and tensile strength of anchor rods were considered in the analysis. Sixteen finite elements simulations were performed considering different combinations of the above mentioned parameters. The results show a fragile response in the base plates when high resistance anchor rods are used. The anchor rods worked as fuse elements in base plates with a large thickness or many stiffeners. Additionally, the models with anchor bars located outside of the column flanges showed lower flexural strength and rotational stiffness compared to the models with anchor rods located between column flanges. The simulations showed that the base plate strength was determined by the simultaneous failure mechanisms of two or more components, different to what is stated in current design guides. Finally, the new method is suitable to design base plates with stiffened and not stiffened configurations, which unlike traditional design methods, show a good adjustment with numerical models.
Cyclic behavior of hollow section beam–column moment connection: Experimental and numerical study
2020, Dr. Nuñez-Castellanos, Eduardo, Boainy, Nwar, González, Freddy, Torres, Ronald, Picón, Ricardo, Guerrero, Néstor
Steel buildings with tubular columns showed a satisfactory performance during the Honshu (2011) earthquake, unlike steel buildings in the 1994 Northridge and 1995 Kobe earthquakes, where welded moment connections showed damage in their joints. In this research, a lateral joint using a hollow structural section (HSS)-beam and HSS-column subjected to cyclic displacement was performed. Three large-scale specimens were tested and a numerical model was calibrated, reaching a good adjustment. Later, several configurations of beams and columns were evaluated using finite element (FE) models from the numerical model previously calibrated. A flexural resistance higher 0.80 Mp at 0.04 [rad] was obtained for all cases studied. The ductility factor in the 3 specimens was lower than 2.5, therefore a non-ductile behavior was controlled in the connection. This aspect is very important although a 0.8 Mp at 0.04 [rad] was achieved. Finally, the typical welded moment connection can be improved using the bolted moment connection, which allows the concentration of inelastic incursion in the beam compared with the welded solution. However, a non-ductile behavior derived from local buckling in flanges of a tubular beam can affect the seismic performance.
Strong column-weak beam relationship of 3D steel joints with tubular columns: Assessment, validation and design proposal
2024, Dr. Nuñez-Castellanos, Eduardo, Mata-Lemus, Ramón
The study of moment connections in steel structures subjected to cyclic loads has been extensively studied, providing a great number of requirements, including the strong column-weak beam relationship, to guarantee a satisfactory cyclic performance. However, investigations on the cyclic performance of moment connections considering the bidirectional and axial load effects simultaneously with tubular columns are limited. This study aims to assess and validate the strong column-weak beam relationship of 3D steel moment connections using reduced order models. The simplified model (reduced order model) approach was employed to extend the range of beam and column elements sizes and reduce the experimental and computational costs. These models were calibrated from full-scale experimental studies. A great number of configurations with different beam and column sizes without loss of reliability and structural representativeness of the studied phenomenon were studied. A total of 13640 simplified models were developed. Results show a cyclic behavior controlled by the strong column-weak beam relationship to modify the joint’s failure mechanism. The increasing of strong column-weak beam relationship and the biaxial effect caused degradation of the strength and stiffness as well as in dissipated energy. An optimal strong column-weak beam relationship was obtained for all joint configurations analyzed. Finally, a robust design procedure is proposed, ensuring the cyclic behavior of end-plate moment connection with built-up box column including biaxial effect and axial load. Therefore, the use of this type of moment connection can be used in special and intermediate moment frames designed according to Seismic provisions.
Bidirectional response of weak-axis end-plate moment connections: Numerical approach
2020, Dr. Nuñez-Castellanos, Eduardo, Parraguez, Guillermo, Herrera, Ricardo
Brittle failure mechanisms can affect the seismic performance of structures composed of intersecting moment resisting frames, if the biaxial effects are not considered. In this research, the bidirectional cyclic response of H-columns with weak-axis moment connections was studied using numerical models. Several configurations of joints with bidirectional effects and variable axial loads were studied using the finite element method (FEM) in ANSYS v17.2 software. The results obtained showed a ductile behavior when cyclic loads are applied. No evidence of brittle failure mechanisms in the studied joint configurations was observed, in line with the design philosophy established in current seismic provisions. However, beams connected to the column minor axis reached a partially restrained behavior. Joints with four beams connected to the column exhibited a partially restrained behavior for all axial load levels. An equivalent force displacement method was used to compare the hysteretic response of 2D and 3D joints, obtaining higher deformations in 3D joints with respect to 2D joints with a similar number of connected beams. Consequently, design procedures are not capable of capturing the 3D deformation phenomenon.
Numerical study on cyclic response of end-plate biaxial moment connection in box columns
2020, Gallegos, Marco, Nuñez-Castellanos, Eduardo, Herrera, Ricardo
The 2008 Wenchuan-China earthquake showed the importance of considering the bidirectional seismic action as a cause of failure in column hinge mechanisms. Subsequently, the large 2011 Tohoku-Japan earthquake revealed that Special Moment Frames buildings, made of tubular columns (Hollow Structural Section or Built-up Box Section) and rigid connections with I-beams, did not suffer serious damage. However, only the ConXtech® ConXL™ moment connection has been prequalified according to the (American Institute of Construction) AISC Seismic Provisions for use with tubular columns and the rest of connections do not consider biaxial resistance. The research reported herein investigated the cyclic response of box-columns joints, connected to I beams using the four-bolt extended endplate connection, subjected to bidirectional bending and axial load on the column. To conduct the study, complex nonlinear finite element models (FEMs) of several I beam to box column joint configurations were constructed and analyzed under cyclic loading using the ANSYS software. The results reveal that the failure is concentrated in the beams of all joint configurations except for the columns with axial load equal to 75% of the column capacity, where a combined failure mechanism is achieved. The energy dissipation capacity of joints with a greater number of beams is lower than joints with fewer beams. The bidirectional effect of the seismic action and the level of axial load must be considered to avoid the formation of a column-hinge fragile failure mechanism also the behavior exhibited by 3D joints is more realistic than 2D joints according to real structures.
Cyclic behavior of concrete-filled tube columns with bidirectional moment connections considering the local slenderness effect
2024, Dr. Nuñez-Castellanos, Eduardo, Mata-Lemus, Ramón
In this research, the cyclic behavior of concrete-filled thin tube (CFTT) columns with bidirectional moment connections was numerically studied within the context of thin-walled structures. Novel considerations in the design of CFTT columns with slenderness sections are proposed through a parametric study. A total of 70 high-fidelity finite element (FE) models are developed using ANSYS software v2022 calibrated from experimental research using similar 3D joint configurations. Furthermore, a comparison of different width-to-thickness ratios in columns was considered. The results showed that the models with a high slenderness ratio reached a stable cyclic behavior until 0.03 rad of drift, and a flexural strength of 0.8 Mp was reached for 4% of the drift ratio according to the Seismic Provisions. However, this effect slightly decreased the strength and the dissipated energy of the moment connection in comparison to columns with a high ductility ratio. Moreover, an evaluation of concrete damages shows concrete cracked for cyclic loads higher than 3% of drift. Finally, the joint configurations studied can achieve a good performance, avoiding brittle failure mechanisms and ensuring the plastic hinges in the beams.
A Simplified Framework to Integrate Databases with Building Information Modeling for Building Energy Assessment in Multi-Climate Zones
2024, Lobos Calquín, Danny, Mata, Ramón, Vielma, Juan Carlos, Beaumont-Sepulveda, Juan Carlos, Mg. Correa-Rogel, Claudio, Dr. Nuñez-Castellanos, Eduardo, Forcael, Eric, Blanco, David, Pulgar, Pablo
BIM models are seldom used for the energy certification of buildings. This paper discusses the advantages of linking two important fields: building information modeling (BIM) and building environmental assessment methods (BEAM), presented as a rating system and a proposal for the Chilean context. The state of the art in both fields around the world is discussed, with an in-depth examination of current BIM software and related applications, followed by a discussion about previous research on integrating them. A lack of interoperability and data losses between BIM and BEM were found. A new tool is presented that addresses these challenges to ensure accurate rating system data, and this new framework is based on database exchange and takes crucial information from BIM to BEAM platforms. The development of the method includes BIM programming (API), database links, and spreadsheets for a Chilean building energy certification through a new tool, also applicable to multiclimactic zones. This new semi-automatic tool allows architects to model their design in a BIM platform and use this information as input for the energy certification process. The potential and risks of this method are discussed. Several improvements and enhancements of the energy certification process were found when incorporating this new framework in comparison to current methodologies.
Load-level isolator model for pallets on industrial storage racks and validation with experimental results
2024, Dr. Maureira-Carsalade, Nelson, Dr. Nuñez-Castellanos, Eduardo, Sanhueza-Cartes, Marcelo, Roco-Videla, Angel
This paper introduces a system allows for seismic isolation of the pallet from the rack in the down-aisle direction, occupies minimal vertical space (5 cm) and ±7.5 cm of deformation range. A conceptual model of the isolation system is presented, leading to a constitutive equation governing its behavior. A first experimental campaign studying the response of the isolation system's components was conducted to calibrate the parameters of its constitutive equation. A second experimental campaign evaluated the response of the isolation system with mass placed on it, subjected to cyclic loading. The results of this second campaign were compared with the numerical predictions using the pre-calibrated constitutive equation, allowing a double-blind validation of the constitutive equation of the isolation system. Finally, a numerical evaluation of the isolation system subjected to a synthetic earthquake of one component. This evaluation allowed verifying attributes of the proposed isolation system, such as its self-centering capacity and its effectiveness in reducing the absolute acceleration of the isolated mass and the shear load transmitted to the supporting beams of the rack.
Cyclic behavior of the column-tree moment connection with weakened plates: A numerical approach
2023, Dr. Nuñez-Castellanos, Eduardo, Matthews, Pablo
The use of column-tree connections is common in controlled shop environments due to their cost-effectiveness in achieving ductile welds. Field bolts are also easy to install and inspect. However, there is currently no prequalification available for these connections, their performance is not fully understood, and the cost of aftermath repairs is still a major concern for owners. In this research, analytical and numerical studies were performed to assess the cyclic behavior considering the effects of the bolted splice location, bolt slippage, and splice plate thickness. Fourteen numerical models using the finite element method in ANSYS software were analyzed to evaluate the nonlinear behavior of moment connection configurations in terms of the strength, stiffness, ductility, energy dissipation, and overall cyclic response. The results showed that appropriately proportioned bolted splice connections can meet the requirements for prequalified moment connections. The models complied with the criteria established in AISC 358 and achieved flexural resistance that was higher than 80% of the beam plastic moment at 4% of the interstory drift ratio. The weakened plates concentrated the inelastic action, which allowed us to prevent the brittle behavior and damage to the column, welding, and other components of the moment connection. Complex geometries or specially fabricated parts were not required, providing a cost-effective way to control seismic-related damage. Also, required repairs are based on the replacement of standard parts, reducing operational detentions in facilities. Finally, the moment connection studied is classified as partially restrained (PR) according to the requirements established in AISC 360.
Cyclic performance of end-plate biaxial moment connection with HSS columns
2020, Dr. Nuñez-Castellanos, Eduardo, Lichtemberg, Roberto, Herrera, Ricardo
This paper presents a numerical study on the seismic performance of end-plate moment connection between I-beam to HSS (hollow structural section) column stiffened by outer diaphragms (EP-HSS). In previous experimental research, this moment connection showed a satisfactory performance according to requirements established in Seismic provisions. However, one type of joint was studied and bidirectional and axial loads were not considered. In this since, several configurations representative of 2D interior joints and 3D interior and exterior joints in a steel building were modeled and subjected to unidirectional or bidirectional cyclic displacements according to protocol in seismic provisions. Firstly, a similar joint configuration was calibrated from experimental data, obtaining an acceptable adjustment. The assessment of seismic performance was based on hysteretic curves, failure mechanisms, stiffness, dissipated energy, and equivalent damping. The results obtained showed a ductile failure modes for 2D and 3D joint configurations with EP-HSS moment connection. The axial load has no significant effect on the moment connection. However, it affects the column strength due to the increase of the stresses in the column wall. Compared with 2D joints, 3D joints reached higher deformations even when a similar number of beams is used. The external diaphragms to the column panel zone provided rigidity in the joints and no degradation of slope for each loop in load/reload segment for elastic loop; therefore, curves without pinching were observed. All inelastic deformation is concentrated mainly in the beams. A moment resistance above 80% of the capacity of the beam at a drift of 4% is achieved in all joints. From the results reached, the use of EP-HSS moment connection with hollow structural section columns is a reliable alternative in seismic zones when steel moment frames are employed.
- «
- 1 (current)
- 2
- 3
- »