Publication:
Load-level isolator model for pallets on industrial storage racks and validation with experimental results

cris.virtual.author-orcid0000-0003-2016-1154
cris.virtual.author-orcid0000-0002-0858-988X
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.departmentFacultad de Ingeniería
cris.virtual.departmentFacultad de Ingeniería
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcidb6d5c77c-bca3-43b7-8a8f-edbcf487b95a
cris.virtualsource.author-orcidff6f1ede-ee9c-4e26-b7b1-b565f97896fd
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.author-orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentb6d5c77c-bca3-43b7-8a8f-edbcf487b95a
cris.virtualsource.departmentff6f1ede-ee9c-4e26-b7b1-b565f97896fd
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department#PLACEHOLDER_PARENT_METADATA_VALUE#
dc.contributor.authorDr. Maureira-Carsalade, Nelson
dc.contributor.authorDr. Núñez-Castellanos, Eduardo
dc.contributor.authorSanhueza-Cartes, Marcelo
dc.contributor.authorRoco-Videla, Angel
dc.date.accessioned2024-11-28T20:24:53Z
dc.date.available2024-11-28T20:24:53Z
dc.date.issued2024
dc.description.abstractThis paper introduces a system allows for seismic isolation of the pallet from the rack in the down-aisle direction, occupies minimal vertical space (5 cm) and ±7.5 cm of deformation range. A conceptual model of the isolation system is presented, leading to a constitutive equation governing its behavior. A first experimental campaign studying the response of the isolation system's components was conducted to calibrate the parameters of its constitutive equation. A second experimental campaign evaluated the response of the isolation system with mass placed on it, subjected to cyclic loading. The results of this second campaign were compared with the numerical predictions using the pre-calibrated constitutive equation, allowing a double-blind validation of the constitutive equation of the isolation system. Finally, a numerical evaluation of the isolation system subjected to a synthetic earthquake of one component. This evaluation allowed verifying attributes of the proposed isolation system, such as its self-centering capacity and its effectiveness in reducing the absolute acceleration of the isolated mass and the shear load transmitted to the supporting beams of the rack.
dc.identifier.doi10.12989/scs.2024.52.1.001
dc.identifier.urihttps://repositorio.ucsc.cl/handle/25022009/11957
dc.languageeng
dc.publisherKorea Institute of Science and Technology Information
dc.rightsregistro bibliográfico
dc.subjectConstitutive numerical model
dc.subjectDouble-blind validation
dc.subjectDown-aisle direction
dc.subjectExperimental tests
dc.subjectPallet isolation
dc.subject.ods11
dc.titleLoad-level isolator model for pallets on industrial storage racks and validation with experimental results
dc.typeartículo
dspace.entity.typePublication
oairecerif.author.affiliationFacultad de Ingeniería
oairecerif.author.affiliationFacultad de Ingeniería
oairecerif.author.affiliationFacultad de Ingeniería
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
Files
License bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
license.txt
Size:
276 B
Format:
Item-specific license agreed to upon submission
Description: